Gas change (drying ironers).
1) Change the nozzle installing the appropriate one for the new gas type, according to instructions given in the use and maintenance handbook.
2) Modify the gas inlet and outlet pressure acting on the solenoid valve (pos. 5 for the inlet pressure and pos. 6 for the outlet pressure), setting the pressures as indicated in the u&m handbook.
Make sure that the gas supply pressure is constant: pressure rushes (even a few mbar) may affect the correct burner working and therefore the temperature control. The pressure must be measured using a digital manometer, since the one working with H2O is not precise enough.
3) When setting is completed, seal the solenoid valve.